88843088 - 88843025 - 88848075 info@hlcgroup.ir
Untitled

واردات

SC-002

ارسال شده توسط واحد فنی

  ماژول SC-002  مبدل جریان به ولتاژ است.

 
SC-002
Voltage to current module 0-2.5 / 3.3 / 5/10/15 / 24V turn 0-20mA rail installation
Product Features
A: to achieve 0 ~ 2.5 / 3.3V / 5V / 10V / 12V / 15V / 24V and other voltage signal is converted to 4 ~ 20ma
    Or 0 ~ 20ma current signal (more than several voltage signals are several typical values, you can
    For any other voltage value, such as 0 ~ 6.5V turn 4 ~ 20ma)
B: 0V corresponds to 4ma or 0ma, 2.5 / 3.3V / 5V / 12V / 24V corresponds to 20ma, the voltage and current
    Fully linear, to meet the national standard signal requirements
C: zero adjustment: adjust the current corresponding to the size of 0V, can be higher or lower than 4ma
    Range adjustment: adjust the input voltage corresponding to the maximum current size, can be higher than
 Working power
Power supply 12V ~ 24V wide power supply, convenient from the microcontroller, PLC and other modules to take power
Wiring 
Power supply: positive then VCC, negative then GND
Current output: current output connected to the sampling module, the figure with the load that
Control voltage: control voltage is the need to convert the voltage signal, the positive then voltage input
(Module commissioning wiring diagram)
A: Connect the power supply, positive to VCC, negative to GND
B: The current output is connected to the required engineering equipment and can be calibrated to access the measuring instrument
   (Such as current output termination ammeter positive ammeter negative access to GND, the formation of the loop)
C: Connect the control voltage, the control voltage is connected to the voltage input, the cathode is connected to GND, according to figure connection
    Voltmeter to facilitate measurement of control voltage size
D: adjust the control voltage is 0V, at this time to adjust the zero adjustment potentiometer to test the ammeter current
    For 4ma
E: Adjust the control voltage to the required maximum voltage (such as 2.5V / 3.3V / 5V / 12V / 24V, etc.)
    At this time to adjust the range adjustment potentiometer to test the ammeter output current of 20ma
F: Debugging is complete

Untitled

نمونه واردات تجهیزات ابزار دقیق و اتوماسیون صنعتی
Endress Hauser , E+H , Hach Lange , Supcon , Rosemount , Kobold , Wika , JUMO , Fluke , Asco , Siemense , Honeywell , Advantech , NI , Moxa , Adlink , National Instrument , JIT , MCC , HBM , Omega , Soway , TML , CTC , Vishay

برچسب , ,

  • آذر ۴, ۱۳۹۵

نوشته شده توسط واحد فنی

واردات تجهیزات ابزار دقیق ، اتوماسیون صنعتی ، سنسور و آموزش نرم فزار Labview

دیدگاه بسته شده است

جهت اطلاع از آخرین اخبار محصولات و مقالات آموزشی در خبرنامه سایت عضو شوید

می خواهم به روز باشم